Outfall Water Quality Changes Over Twenty-five Years at an Industrial Site in Response to Stormwater Controls, Part 2
GeoSyntec Consultants, USA
California State Polytechnic University, USA
Wright Water Engineers Inc., USA
WRA Consultants, USA
University of California, USA
Abstract
This paper describes a unique case study and is the second part of a two-part set. This paper presents the overall trends in outfall stormwater quality conditions over a 25-year period in response to site changes and stormwater treatment at the Santa Susana Field Laboratory. The first paper (Pitt et al. 2026) described the site historical activities, interim contaminated soil and material removal actions, and stormwater management activities. In this paper, the outfall concentrations were compared to the permit and benchmark numeric effluent limits contained in the 2015 National Pollutant Discharge Elimination System Permit. The numbers of observations greater than the permit limits during the monitoring period were examined comparing the early monitoring period (1998/99 to 2009/10 rain years) before most of the interim contaminated material removal activities and stormwater management at the site vs. the later monitoring period (2010/11 to 2022/23 rain years) since most of these site changes have occurred. Numerous graphical and statistical analyses were conducted that indicated significant decreases in the number of concentration observations greater than the 2015 permit limits since the interim contaminated material removal and stormwater management activities began at the site. Site modeling has started to quantify stormwater discharge benefits of future contaminated soil clean-up.
1 Regulated Outfall Monitoring Programs
The Santa Susana Field Laboratory (SSFL) occupies 1,153 ha (2,849 acres) in the Simi Hills of Ventura County, California, in the southern part of the state near Los Angeles. SSFL is a former rocket engine test and nuclear energy research facility. The site is jointly owned by the Boeing Company and the U.S. federal government. The National Aeronautics and Space Administration (NASA) administers the portion of the property owned by the federal government. The industrial activities at SSFL have ceased, and current activities include environmental monitoring and sampling, demolition, remediation, and ongoing remedial planning. Undeveloped land and open space provide wildlife habitat and natural areas. Contaminated soil remains distributed and exposed across the site, which is the basis for regulating stormwater, despite the lack of current active industrial operations.
Stormwater discharges from SSFL are currently regulated by an individual discharge permit from the Los Angeles Regional Water Quality Control Board (LARWQCB) under the NPDES Permit No. CA0001309 for the Boeing Company, SSFL, Canoga Park, CA. This paper references the “2015 Permit” (Order No. R4-2015-0033) (LARWQCB 2015) and uses the permit limits included in that permit version for the statistical analyses shown later in this paper, as the 2023 permit (effective January 1, 2024) was not available at that time of the analyses. The 2015 permit required composite sampling at the 12 surface water outfalls during every storm that produces runoff. Table 1 lists the numeric effluent limits (NELs) for each outfall contained in the 2015 discharge permit, while Table 2 lists some of the permit criteria listed for protection of human health and aquatic life, or as listed in the regional Basin Plan. Table 3 lists the number of concentration observations recorded as required by this permit at the time of preparation of this paper. About 43,000 concentration values for constituents with permit limits that were included in the 2015 permit were recorded over the 25 years at the 12 outfalls. Table 3 also shows the number of rain events that were associated with these observations. Besides the constituents having NELs, many others are also routinely monitored as required by the discharge permit, including more than 250 constituents that are analyzed at every outfall at least once annually. More than 70,000 analytical results for all constituents have been obtained from the outfalls during that time. Complete data and descriptions are contained in the monitoring reports submitted to the LARWQCB (https://www.boeing.com/principles/environment/santa-susana/monitoring-reports.page).
Table 1 Numeric Effluent Limits (NELs) in 2015 SSFL NPDES discharge permit (all permit limits except for Outfalls 001 and 002 that are benchmarks) (LARWQCB 2015).
| Analyte | Units | Outfalls 003, 004, 005, 006, 007, 009, and 010 |
Outfall 008 | Outfalls 011, 001, 018, and 002 |
| pH (field) (acceptable range) | SU | 6.5 to 8.5 | 6.5 to 8.5 | 6.5 to 8.5 |
| Temperature | °F | 86 | 86 | 86 |
| Total Dissolved Solids | mg/L | 850 | 950 | 950 |
| Chloride | mg/L | 150 | 150 | 150 |
| Biochemical Oxygen Demand (BOD) | mg/L | n/a | n/a | 30 |
| Total Residual Chlorine | mg/L | n/a | n/a | 0.1 |
| Oil & Grease | mg/L | 15 | 15 | 15 |
| Sulfate | mg/L | 250 | 300 | 300 |
| Fluoride | mg/L | n/a | 1.6 | 1.6 |
| Surfactants (MBAS) | mg/L | n/a | n/a | 0.5 |
| Chronic Toxicity, Selenastrum | % | 50 | 50 | 50 |
| Ammonia as Nitrogen (N) | mg/L | n/a | 10.1 | 10.1 |
| Nitrate + Nitrite as Nitrogen (N) | mg/L | 10 | 8 | 8 |
| Nitrate as Nitrogen (N) | mg/L | n/a | 8 | 8 |
| Nitrite as Nitrogen (N) | mg/L | n/a | 1 | 1 |
| Combined Radium-226 and Radium-228 | pCi/L | 5 | 5 | 5 |
| Gross Alpha | pCi/L | 15 | 15 | 15 |
| Gross Beta | pCi/L | 50 | 50 | 50 |
| Strontium-90 | pCi/L | 8 | 8 | 8 |
| Tritium | pCi/L | 20000 | 20000 | 20000 |
| Antimony | µg/L | 6 | 6 | n/a |
| Arsenic | µg/L | n/a | n/a | 10 |
| Barium | mg/L | n/a | 1 | 1 |
| Beryllium | µg/L | n/a | n/a | 4 |
| Cadmium | µg/L | 4 | 3.1 | 3.1 |
| Chromium VI | µg/L | n/a | n/a | 16 |
| Copper | µg/L | 13 | 14 | 14 |
| Iron | mg/L | n/a | n/a | 0.3 |
| Cyanide | µg/L | 9.5 | 9.5 | 8.5 |
| Lead | µg/L | 5.2 | 5.2 | 5.2 |
| Manganese | µg/L | n/a | n/a | 50 |
| Mercury | µg/L | 0.13 | 0.13 | 0.1 |
| Nickel | µg/L | 86 | 86 | n/a |
| Selenium | µg/L | n/a | 5 | 8.2 |
| Thallium | µg/L | 2 | 2 | n/a |
| Zinc | µg/L | 120 | 120 | 119 |
| 1,1-Dichloroethene | µg/L | n/a | n/a | 6 |
| 1,2-Dichloroethane | µg/L | n/a | n/a | 0.5 |
| 2,4-Dinitrotoluene | µg/L | n/a | n/a | 18 |
| 2,4,6-Trichlorophenol | µg/L | n/a | n/a | 13 |
| alpha-BHC | µg/L | n/a | n/a | 0.03 |
| bis (2-ethylhexyl) Phthalate | µg/L | n/a | n/a | 4 |
| n-Nitrosodimethylamine | µg/L | n/a | n/a | 16 |
| Pentachlorophenol | µg/L | n/a | n/a | 16.5 |
| Perchlorate | µg/L | 6 | 6 | 6 |
| TCDD TEQ No DNQ* | µg/L | 2.8×10-08 | 2.8×10-08 | 2.8×10-08 |
| Trichloroethene | µg/L | n/a | n/a | 5 |
Note that some limits are not simple comparisons against the concentration observations. For example:
- If hexavalent chromium is analyzed along with total chromium, the limit is only applied to hexavalent chromium and not to total chromium.
- For gross alpha, the limit is compared against the calendar year average. These results may also trigger speciation analyses that are performed for individual samples to identify anthropogenic vs. natural sources of the alpha emitters.
- Chronic toxicity is reported as pass/fail and percent effect. An exceedance requires both a “fail” and percentage effect greater than 50%.
Regulatory exceedances are only applied to the permit limits and not to the benchmarks at Outfalls 001 and 002. High benchmark values are also reported, including evaluations and discussions on possible sources and responses (as with the permit limits), but fines are not imposed.
Table 2 Example criteria rational provided in 2015 SSFL NPDES Discharge Permit, Reasonable Potential Analysis, Criteria Pollutant, and Toxics Emissions Reporting (CTR) (LARWQCB 2015, Attachment J).*
| Analyte | Units | Freshwater aquatic life** | Human health*** | Basin plan**** |
| Antimony | µg/L | none | 14 | 6 |
| Arsenic | µg/L | 150 chronic/340 acute | none | 10 |
| Beryllium | µg/L | none | narrative | 4 |
| Cadmium | µg/L | 2.5 chronic/4.5 acute* | narrative | 5 |
| Copper | µg/L | 9.3 chronic/14 acute* | 1300 | |
| Lead | µg/L | 3.2 chronic/81.6 acute* | narrative | |
| Mercury | µg/L | reserved | 0.05 | 2 |
| Nickel | µg/L | 52 chronic/469 acute* | 610 | 100 |
| Selenium | µg/L | 5 chronic | narrative | 50 |
| Thallium | µg/L | none | 1.7 | 2 |
| Zinc | µg/L | 120 chronic and acute* | none | |
| TCDD TEQ No DNQ | µg/L | not shown | 1.30X10-08 | 0.00003 |
| Trichloroethene | µg/L | none | 2.7 | 5 |
Table 3 Numbers of concentration measurements and events recorded per SSFL outfall location since the 1998 discharge permit.
| Outfall | Total number of measured concentrations | Approximate number of total events |
| 001 | 5,083 | 107 |
| 002 | 9,056 | 222 |
| 003* | 2,457 | 67 |
| 004* | 2,883 | 85 |
| 005* | 2,693 | 88 |
| 006* | 3,426 | 98 |
| 007* | 1,538 | 53 |
| 008 | 2,902 | 83 |
| 009* | 4,299 | 137 |
| 010* | 1,542 | 43 |
| 011 | 3,272 | 46 |
| 018 | 3,755 | 80 |
| total | 42,906 | 222 |
2 Statistical Methodology and Observed Trends of High Outfall Stormwater Concentrations with Time and Site Activities
The SSFL stormwater database is maintained by Geosyntec Consultants and includes all the outfall data annually submitted to the LARWQCB for all outfalls (Boeing 2021a; 2021b; 2022a; 2022b). The sampling and analysis plans (SPAs) are also routinely submitted (MWH 2015; Haley and Aldrich 2021). Site-wide workplans and data reports are also annually submitted (Santa Susana Surface Water Expert Panel and Geosyntec Consultants 2015; 2019). The database was used in Excel to sort the data according to outfall, constituent, and sampling date. The sorted data were evaluated using various statistical tools (timeseries regression analyses with ANOVA in Excel, probability plots using Minitab, box and whisker plots using SigmaPlot, along with comparison tests, such as t-tests using Excel and non-parametric Mann-Whitney rank sum tests using Minitab). The results of these analyses are summarized in the following sections of this paper to illustrate and quantify the trends and differences in the monitored outfall stormwater constituent concentrations for the different site conditions. A prior set of papers (Pitt et al. 2021; 2022) described design and long-term performance details for the distributed stormwater controls at SSFL.
As described in the first paper of this series (Pitt et al. 2026), many site activities and stormwater treatment efforts have occurred at SSFL over many years to reduce the discharge of stormwater constituents of concern (COCs), while awaiting final site clean-up direction from the California Environmental Protection Agency, Department of Toxic Substances Control (DTSC). This section describes how the stormwater discharge quality at the regulated outfalls responded to these efforts. Table 4 illustrates the timeline of interim contaminated material removal, stormwater controls, and wildfires affecting the outfall drainage areas, while Figure 1 shows the changes in the number of outfall permit limit and benchmark exceedances since 1998.
Table 4 Site contaminated material and soil removal, advanced stormwater treatment systems, distributed stormwater controls, and site wildfires timeline for SSFL outfall drainage areas.
| Site Activity | Type of Activity | Northern Outfalls | |||||||||||
| OF003 | OF004 | OF005 | OF006 | OF007 | OF010 | OF008 | OF009 | OF001 (Below OF011) | OF011 | OF002 (Below OF018) | OF018 | ||
| Sodium Disposal Facility (burn pit) soil removal | contaminated material removal | 2000 | 2000 | 2000 | |||||||||
| Interim soil removal and perchlorate treatment | contaminated material removal | 2003 | 2003 | ||||||||||
| Topanga fire | wildfires on site | 2005 | 2005 | 2005 | 2005 | 2005 | 2005 | 2005 | 2005 | 2005 | 2005 | 2005 | 2005 |
| Northern Drainage debris removal | contaminated material removal | 2007 | |||||||||||
| Distributed stormwater controls | stormwater treatment systems | 2009 | 2009 | ||||||||||
| Interim/source removal actions (ISRA) at OF008 | contaminated material removal | 2010 | |||||||||||
| Advanced stormwater treatment system at OF018 in operation | stormwater treatment systems | 2011 | 2011 | 2011 | 2011 | 2011 | 2011 | 2011* | 2011 | ||||
| Interim/source removal actions (ISRA) at OF009 | contaminated material removal | 2013 | |||||||||||
| NASA demolition and contaminated material removal - structures removal | contaminated material removal | 2015 | 2015 | 2015 | |||||||||
| Boeing building demolition and asphalt removal | contaminated material removal | 2015 | 2015 | 2015 | 2015 | 2015 | 2015 | 2015 | |||||
| NASA demolition and contaminated material removal - structures removal | contaminated material removal | 2017 | 2017 | ||||||||||
| Woolsey fire | wildfires on site | 2018 | 2018 | 2018 | 2018 | 2018 | |||||||
| Treated wood pole barriers | stormwater treatment systems | 2019 | 2020 | 2020 | 2019 | ||||||||
| NASA demolition and contaminated material removal - structures removal | contaminated material removal | 2019 | |||||||||||
| NASA demolition and contaminated material removal - structures removal | contaminated material removal | 2019 | 2021 | 2021 | |||||||||
| Advanced stormwater treatment system at OF011 in operation** | stormwater treatment systems | 2021 | |||||||||||
| Utility pole removal | contaminated material removal | 2022 | 2022 | 2022 | |||||||||

Figure 1 Summary of SSFL permits, Surface Water Expert Panel involvement, and water quality compared to 2015 permit limits, 1998–2022.
Notable milestones on the Figure 1 time series plot include:
- 1998 NPDES permit: NPDES Permit No. CA0001309 was issued to regulate wastewater and stormwater discharged from SSFL.
- 2004 NPDES permit: The 2004 permit included new California Toxics Rule (CTR)
-based effluent limits and added 11 new compliance monitoring locations. - 2005 Topanga wildfire: Approximately 97% of SSFL burned.
- 2006 NPDES permit: The 2004 permit was revised to include the waste load allocations (WLAs) specified by applicable TMDLs of downstream waterbodies.
- 2007 Cease and desist order (CDO): In the CDO, the LARWQCB required the “assembly of a panel to review site conditions, modeled flow, contaminants of concern, and evaluate the BMPs capable of providing treatment to meet the final effluent limits.” The CDO also required stormwater control planning, performance evaluation, and reporting requirements.
- 2010 NPDES permit: No major changes to the permit. The Expert Panel continued to make data-informed recommendations for stormwater controls in the Outfall 008 and 009 Watersheds, which were then implemented at the site.
- In 2011, following the construction of the Outfall 018 advanced stormwater treatment system, stormwater from Outfalls 003 through 007 and Outfall 010 was retained in storage tanks and then transferred to the Silvernale Pond before being treated by the advanced stormwater treatment system. Paved helipad areas at Outfall 009 are also diverted to the Silvernale advanced treatment system.
- 2015 NPDES permit: The permit expanded the Expert Panel’s charge to all regulated SSFL Outfalls. In response, the Panel continues to review permit limits and benchmark exceedances at all outfalls, making data-driven stormwater control recommendations on a site-wide basis.
- 2018 Woolsey wildfire: Approximately 80% of SSFL was impacted by this wildfire, and the site received above-average rainfall in 2018/19. Because of the post-fire hydrophobicity of the soil and loss of vegetative cover, rain events following the fire produced significantly greater runoff volumes as well as an increase in the number of permit limit and benchmark exceedances compared to rain events of similar size during non-fire years. Stormwater runoff volumes and water quality across the SSFL site returned to typically observed conditions the following year.
- 2022/2023 record rains: The 2022/23 rain year had a total of 1,120 mm (44.4 inches) of rainfall, a record compared to 57 years of rainfall monitoring data. The long-term average rainfall at SSFL is 434 mm (17.1 inches). Fourteen exceedances were recorded during this period (12 were for aesthetic-based permit limits and benchmarks for Fe and Mn, while 2 were for TCDD TEQ no DNQ).
2.1 Outfall trends associated with rains
The annual rain totals during the 25-year period shown on Figure 1 ranged from about 114 to 1,130 mm (4.49 to 44.5 inches). The following analyses focus on the comparison of numbers of concentration observations greater than the 2015 NELs (as a normalizing method) with site conditions (removal of contaminated materials) and the use of stormwater management practices. Most of these sites have interim contaminated soil and material removal activities and stormwater management changes have occurred since the 2010/11 rain year. Therefore, basic analyses compare the observed stormwater quality from 1998/99 to 2009/10 as the early period before site changes occurred vs. from 2010/11 to 2022/23, as the later period after the site changes occurred, along with changes in long-term continuous trends.
It is possible that changes in site rainfall conditions during these two periods may affect stormwater runoff quality. Therefore, the rainfall during these two periods is described and compared in Table 5 and Figure 2. These data indicate that the annual rainfall amounts were very similar during these two periods, as shown by no apparent or statistically significant (p = 0.41) changes in the regression slope term of rainfall amount vs. time since the monitoring started, and by overlapping probability plots of the rainfall amounts in the two periods. Nonparametric Mann-Whitney statistical comparison tests also found no significant differences (p = 0.87) in the yearly rainfall amounts for these two periods.
Table 5 Annual rainfall characteristics at SSFL before and after Interim contaminated material removal and stormwater management.
| Annual rainfall depths (mm and inches) | Early rain period (1998/99 to 2009/10) | Late rain period (2010/11 to 2022/23) |
| Minimum | 152 (5.98) | 114 (4.49) |
| Maximum | 711 (28.0) | 1128 (44.41) |
| Median | 448 (17.6) | 305 (12.0) |
| Average | 420 (16.5) | 432 (17.0) |
| Standard deviation | 177 (7.0) | 280 (11.0) |
| Coefficient of variation (COV) | 0.42 | 0.65 |
| Rain depth during years of Topanga (early period) and Woolsey (late period) fires | 533 (21.0) | 668 (26.3) |

Figure 2 Time series, probability, and box and whisker plots of annual rainfall amounts, before and after interim contaminated material removal and stormwater management at SSFL.
Figure 3 shows scatterplots of the numbers of concentration observations that were greater than the 2015 NELs per year vs. annual rainfall, excluding the two years with large fires. Both plots show significant relationships with increasing observations greater than the 2015 NEL values with increasing annual rain amounts (p of the regression slopes were both <0.02, with insignificant intercept terms). However, the early period, before most of the interim contaminated material removal and stormwater management at the site, had an average slope coefficient more than eight times greater than the slope coefficient during the later period (early period slope term: 0.14 relative slope with a 95% confidence interval of 0.03 to 0.26, and later period slope term: 0.016 relative slope with a 95% confidence interval of 0.007 to 0.025), indicating much more stable site conditions with decreased erosion of contaminated material, and the robustness of the stormwater controls, even for large rains during the later monitoring period.

Figure 3 Annual sum of observations greater than the 2015 NELs compared to annual rain depth (mm) before and after interim contaminated material removal and stormwater management at SSFL, excluding two years with fires.
The rain year including the Topanga fire in 2005 had 533 mm (21.0 in) of rainfall and resulted in 92 concentration observations greater than the 2015 NELs, while the previous rain year had the largest number of observations greater than the 2015 NELs during the early monitoring period (135). The rain year with the Woolsey fire in 2018 had 668 mm (26.3 in) of rainfall with 59 concentration observations greater than the 2015 NELs which was the largest number during the later monitoring period. Therefore, the two fires resulted in large counts of high concentrations with similar rainfall totals, but the early Topanga fire large number of high concentrations was exceeded by another year. In contrast, the rain year with the Woolsey fire was associated with large counts of high concentrations compared to other years in the later monitoring period (more than three times greater than the other rain years in the later rain period) but was substantially less than the number of high concentrations during the earlier Topanga fire year.
Figure 3 also shows that the largest rainfall on record (1,128 mm, 44.4 in, during the 2022/23 rain year) did not have an unusual number of high concentration observations compared to the relatively flat trend line plotted for the late monitoring period. Figure 4 shows the number of qualifying rain events per year during the later rain period, as defined in the 2015 permit for the events requiring compliance monitoring. There is no obvious (or statistically relevant) trend in this plot. During this period, there were 4 to 14 (average of 9.5) qualifying rain events per year associated with 114 to 1,130 mm (4.5 to 44.4 in) of rain per year. The record 2022/23 rain year did not have an unusually high number of qualifying rain events (10 events compared to the average of 9.5), but most of the individual rains occurring during that year were unusually large.

Figure 4 Number of qualifying rain events vs. total annual rain depth (later rain period).
Similar evaluations were conducted comparing relationships of high stormwater concentrations with recurrent interval storms. Generally, the highest SSFL stormwater concentrations were associated with intermediate sized events having recurrent intervals of about one or two years, with more frequent and less frequent events having lower concentrations. The SSFL site is routinely inspected and any locations with potentially high erosion losses are quickly stabilized, which was especially important during the very large rains occurring during the 2022/23 rain year.
Therefore, it is apparent that the number of concentration observations greater than the 2015 NELs were significantly greater during the early period before interim contaminated material removal and stormwater management at SSFL compared to the later period. These differences were not likely associated with differences in the annual rain depths or the number of qualifying rain events for monitoring. The two fires on SSFL both resulted in large numbers of concentration observations greater than the 2015 NELs. Another rain year during the early period had more high concentration observations (135 high observations) than the 2015 NELs compared to the rain year after the Topanga fire results (92 high observations). However, the rain year following the later 2018 Woolsey fire resulted in the largest number of concentration observations greater than the 2015 NELs during the later period (59 high observations). In addition, the record 2022/23 rain year did not result in an unusually large number of high concentrations (14) when compared to the trend of high observations vs. rainfall for the later monitoring period.
2.2 Topanga and Woolsey fires
The Topanga fire started on September 28 and was fully contained on October 6, 2005. It burned 9,783 ha (24,175 acres) in the region, including almost all SSFL. The Woolsey fire started on November 8 and was fully contained on November 21, 2018, after burning 39,234 ha (96,949 acres) in the area. About 80 percent of SSFL was directly affected by the Woolsey fire (watersheds above Outfalls 001, 002, 008, 011, and 018, plus a small portion of the watershed above Outfall 009). The northern outfall watersheds (above Outfalls 003 through 007 and 010) were not directly affected by the fire. Increased occurrences of high concentrations above the 2015 NELs in the stormwater were observed for the remainder of the rain year having these fall season fires, with typical stormwater conditions observed during the following rain year. During the early monitoring period, the Topanga fire caused the largest increases in high concentrations for copper, strontium-90, lead, and TCDD (TEQ no DNQ). The watersheds were all about evenly affected after the Topanga fire. During the late monitoring period, the Woolsey fire caused the largest increases in high concentrations for mercury, gross alpha, copper, and lead. As noted, not all the SSFL watersheds were directly affected by the Woolsey fire. The watersheds above Outfalls 008 and 002 had the largest increases in high stormwater concentrations above the 2015 NELs after the Woolsey fire, with fewer increases in the Outfall 011 and 001 watershed areas, and no reported increases in the Outfall 018 watershed stormwater associated with the Woolsey fire.
2.3 Trends associated with all outfalls combined
The following discussion summarizes the trends of the high concentration observations for the different groups of outfalls. Figure 5 presents trends with time and other comparisons of concentration observations greater than the 2015 NELs for all site outfall data combined, excluding the two years with the Topanga and Woolsey fires. The regression slope term is not statistically significant (p = 0.11) but shows apparent decreasing observations greater than the 2015 NELs with time, although with a large amount of data scatter. The probability plots show overlapping confidence intervals for years having small numbers of observations greater than the 2015 NELs but are widely separated for the years with larger numbers of high concentration observations. The box and whisker plots show large differences in the numbers of observations greater than the 2015 NELs for the two monitoring periods, with a corresponding significant Mann-Whitney Rank Sum test p value for years without the fires (p = 0.014), and when the fire years are considered (p = 0.022). An additional check calculated the paired t-tests of early vs. late monitoring periods of each outfall, which also resulted in a significant p value (<0.001). The slope and rank sum comparison p-values are shown for the years without the fires, and for the years including the fires. Overall, decreasing observations greater than the 2015 NELs with time indicate improving conditions with the stormwater management and interim contaminated material removal during the later monitoring period.

Figure 5 Trends of the numbers of concentration observations greater than the 2015 NELs for all outfalls combined.
The following discussions show similar plots and data for the individual outfalls. They are shown without the two years with fires to better focus on changes associated with the interim contaminated material removal and stormwater management activities, although the slope and rank sum comparison p-values are shown for both with and without the fire years.
2.4 Northern outfalls (Outfalls 003, 004, 005, 006, 007, and 010 combined)
The northern outfall drainage areas (Outfalls 003 through 007 and 010) are all small but had many administrative and energy research activities overseen by the USDOE located in their watershed areas. Interim contaminated material and soil removal activities have occurred in these areas. The Topanga fire affected most of SSFL in 2005, including these areas, but the 2018 Woolsey fire did not directly affect these drainage areas. Since 2012, stormwater runoff from these northern areas has been transferred to the Silvernale Pond for treatment at an advanced stormwater treatment system prior to discharge at Outfall 018. The advanced stormwater treatment facility includes stormwater ponds that provide flow equalization and pretreatment by sedimentation followed by ActiFlo coagulation and associated filtration systems. The Silvernale treatment system was not operated during the 2018/19 rain year due to damage from the Woolsey fire. Run-off quantities greater than the capacity of the storage and transfer systems at the northern outfalls are discharged at Outfalls 003 through 007 and at Outfall 010 which have media bed filters. Only infrequent discharges occur at these northern outfalls after the diversion facilities were installed in 2012.
Table 6 shows the 2015 numeric effluent limits that were used to normalize the counts of high constituent observations with time, and the threshold type (permit limit or benchmark). The ratios shown are the observed concentrations compared to the 2015 numeric effluent limit (NEL) threshold, although many of the permit limits have changed with time. These 2015 limits are used to examine the concentration trends of these constituents. The maximum observed ratios (observed concentration compared to the 2015 NEL threshold limits) are shown along with the total count of ratios greater than 1.0, along with counts of high ratios before vs. during, and after the 2010/11 rain year.
Constituents with concentrations that were never observed to be greater than the 2015 NELs are not listed on these tables. Mercury, lead, copper, and dioxin (measured as TCDD TEQ No DNQ) had the largest number of high ratios at these northern outfalls, almost all occurring in the early data period.
The numbers of observed concentrations that were greater than the 2015 permit limits are seen to significantly decrease with time, as seen on the time series, probability, and box and whisker plots on Figure 6. The probability plots compare early with later rain period total numbers of these high observations and are also seen to be very distinct, with the later period rain years having close to zero observations greater than the 2015 NELs. The significance of the slope term when these numbers of observations are regressed with time are all significant (all northern outfalls combined having p = 0.038 without fire years and p = 0.027 when the fire years are considered). In addition, the nonparametric Mann Whitney Rank Sum test compared the high concentration observation counts greater than the 2015 NELs for the period before 2011 compared to later data also indicated significant differences (p = 0.001) with and without considering the years with the fires.
Table 6 Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL northern outfalls.
| Total Dissolved Solids | Chloride | Nitrate + Nitrite as Nitrogen (N) | Oil & Grease | Gross Beta | Strontium-90 | Antimony | Cadmium | |
| Threshold maximum 2015 (NEL) | 850 mg/L | 150 mg/L | 10 mg/L | 15 mg/L | 50 pCi/L | 8 pCi/L | 6 µg/L | 4 µg/L |
| Threshold type 2015 (NEL) | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit |
| Max observed ratio OF003 | 1.00 | <1 | <1 | <1 | 1.13 | 1.35 | 5.83 | <1 |
| Count >2015 NEL | 1 | 0 | 0 | 0 | 1 | 2 | 1 | 0 |
| Count before 2010–2011 rain year | 1 | 0 | 0 | 0 | 1 | 2 | 1 | 0 |
| Count during Topanga fire year | 1 | 0 | 0 | 0 | 0 | 1 | 1 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF004 | <1 | <1 | <1 | <1 | 1.25 | <1 | <1 | <1 |
| Count >2015 NEL | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 |
| Count before 2010–2011 rain year | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF005 | 1.15 | 1.07 | 5.10 | <1 | <1 | <1 | 1.33 | <1 |
| Count >2015 NEL | 1 | 1 | 7 | 0 | 0 | 0 | 4 | 0 |
| Count before 2010–2011 rain year | 1 | 1 | 7 | 0 | 0 | 0 | 4 | 0 |
| Count during Topanga fire year | 1 | 1 | 6 | 0 | 0 | 0 | 0 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF006 | <1 | 1.40 | 1.30 | 2.03 | 1.28 | <1 | <1 | <1 |
| Count >2015 NEL | 0 | 2 | 1 | 1 | 1 | 0 | 0 | 0 |
| Count before 2010–2011 rain year | 0 | 2 | 1 | 1 | 1 | 0 | 0 | 0 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF007 | <1 | <1 | <1 | <1 | 5.88 | <1 | 1.83 | 1.00 |
| Count >2015 NEL | 0 | 0 | 0 | 0 | 2 | 0 | 4 | 1 |
| Count before 2010–2011 rain year | 0 | 0 | 0 | 0 | 2 | 0 | 4 | 1 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF010 | <1 | 1.00 | <1 | <1 | <1 | <1 | 3.33 | <1 |
| Count >2015 NEL | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 0 |
| Count before 2010–2011 rain year | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 0 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio 003 to 007 plus 010 | 1.15 | 1.40 | 5.10 | 2.03 | 5.88 | 1.35 | 5.83 | 1.00 |
| Count >2015 NEL | 2 | 4 | 8 | 1 | 5 | 2 | 10 | 1 |
| Count before 2010–2011 rain year | 2 | 4 | 8 | 1 | 5 | 2 | 10 | 1 |
| Count during Topanga fire year | 2 | 1 | 6 | 0 | 0 | 1 | 3 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
Table 6 (cont.) Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL northern outfalls .
| Copper | Cyanide | Lead | Mercury | Thallium | Zinc | TCDD TEQ No DNQ | Total | |
| Threshold maximum 2015 (NEL) | 13 µg/L | 9.5 µg/L | 5.2 µg/L | 0.13 µg/L | 2 µg/L | 120 µg/L | 2.8×10-8 µg/L | |
| Threshold type 2015 (NEL) | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | |
| Max observed ratio OF003 | 1.31 | <1 | 2.12 | 1.54 | <1 | <1 | 13.47 | |
| Count >2015 NEL | 2 | 0 | 1 | 7 | 0 | 0 | 1 | 16 |
| Count before 2010–2011 rain year | 2 | 0 | 1 | 6 | 0 | 0 | 1 | 15 |
| Count during Topanga fire year | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 5 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF004 | 1.15 | <1 | <1 | 24.62 | <1 | <1 | 157.82 | |
| Count >2015 NEL | 1 | 0 | 0 | 20 | 0 | 0 | 9 | 31 |
| Count before 2010–2011 rain year | 1 | 0 | 0 | 20 | 0 | 0 | 9 | 31 |
| Count during Topanga fire year | 0 | 0 | 0 | 2 | 0 | 0 | 5 | 7 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF005 | 2.31 | <1 | 6.54 | 61.85 | 1.55 | <1 | 171.43 | |
| Count >2015 NEL | 3 | 0 | 3 | 18 | 1 | 0 | 4 | 42 |
| Count before 2010–2011 rain year | 3 | 0 | 3 | 18 | 1 | 0 | 4 | 42 |
| Count during Topanga fire year | 2 | 0 | 2 | 1 | 0 | 0 | 2 | 15 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF006 | 2.62 | 1.01 | 5.58 | 6.85 | <1 | <1 | 2048.26 | |
| Count >2015 NEL | 2 | 1 | 2 | 10 | 0 | 0 | 3 | 23 |
| Count before 2010-2011 rain year | 2 | 1 | 2 | 10 | 0 | 0 | 3 | 23 |
| Count during Topanga fire year | 2 | 0 | 2 | 2 | 0 | 0 | 1 | 7 |
| Count during and after 2010-2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF007 | 1.92 | <1 | 3.85 | 4.08 | <1 | <1 | 1.26 | |
| Count >2015 NEL | 4 | 0 | 3 | 8 | 0 | 0 | 2 | 24 |
| Count before 2010-2011 rain year | 4 | 0 | 3 | 8 | 0 | 0 | 2 | 24 |
| Count during Topanga fire year | 2 | 0 | 2 | 0 | 0 | 0 | 1 | 6 |
| Count during and after 2010-2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio OF010 | 1.62 | <1 | 15.19 | 2.77 | <1 | 1.34 | 9.28 | |
| Count >2015 NEL | 2 | 0 | 6 | 5 | 0 | 1 | 12 | 28 |
| Count before 2010-2011 rain year | 2 | 0 | 5 | 5 | 0 | 0 | 11 | 25 |
| Count during Topanga fire year | 1 | 0 | 1 | 0 | 0 | 0 | 2 | 5 |
| Count during and after 2010-2011 rain year | 0 | 0 | 1 | 0 | 0 | 1 | 1 | 3 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
| Max observed ratio 003 to 007 plus 010 | 2.62 | 1.01 | 15.19 | 61.85 | 1.55 | 1.34 | 2048.26 | |
| Count >2015 NEL | 14 | 1 | 15 | 68 | 1 | 1 | 31 | 164 |
| Count before 2010-2011 rain year | 14 | 1 | 14 | 67 | 1 | 0 | 30 | 160 |
| Count during Topanga fire year | 8 | 0 | 8 | 5 | 0 | 0 | 11 | 45 |
| Count during and after 2010-2011 rain year | 0 | 0 | 1 | 1 | 0 | 1 | 1 | 4 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |

Figure 6 Time series and probability plots for numbers of high concentrations per year at SSFL Northern Outfalls.
2.5 Outfalls 008 and 009
When the Surface Water Expert Panel began its work at the site in 2007, their efforts focused on the Outfall 008 and 009 watersheds, as per the directive of the cease-and-desist order that created the panel. Specifically, because these watersheds are steep and rugged, they did not lend themselves to the construction of new storage facilities coupled with large, advanced treatment systems like those at Outfalls 011 and 018. The panel initially evaluated the feasibility of building dams to store stormwater and found these to be infeasible due to their required size (dam heights of 12 m, or 40 ft, or more would be necessary to provide adequate storage given the steep watersheds), spillway requirements, environmental impacts to construct, and safety concerns with residential neighborhoods immediately downslope from SSFL. This prompted the need for widely distributed and smaller stormwater quality control practices in the Outfall 008 and 009 watersheds. These were initially referred to as “Engineered Natural Treatment Systems” or “ENTS” in the cease-and-desist order. Working closely with Geosyntec, the panel developed conceptual designs for multiple ENTS facilities, such as for the liquid oxygen (LOX) plant area in the Outfall 009 watershed and located in and adjacent to the Northern Drainage. These original ENTS designs evolved into the ISRA clean-up program, and the distributed controls currently used in these watersheds, and the term ENTS was dropped from further use by the panel and other groups involved with stormwater management at the site.
Stormwater runoff from the Outfall 008 and 009 watersheds is therefore not captured and treated by a central stormwater treatment system, except for a portion of the paved helipad area in Area II in the Outfall 009 watershed, which is pumped to the Silvernale Pond and treated by the Outfall 018 advanced stormwater treatment system. Distributed stormwater treatment and an iterative, adaptive management-based approach has therefore been used within both the Outfall 008 and 009 watersheds, as described previously in the prior paper of this series (Pitt et al. 2026).
Stormwater from Happy Valley in the Outfall 008 watershed flows via Dayton Canyon Creek to Chatsworth Creek, which flows south to join Bell Creek southwest of the intersection of Shoup Avenue and Sherman Way. Bell Creek then continues southeast toward its confluence with the Los Angeles River. The Outfall 008 watershed had industrial activity, mainly in the Happy Valley area. This area had an interim soil removal and perchlorate treatment effort in 2003. This area was also affected by the Topanga fire in 2005. Distributed controls (mainly erosion control and dirt road stabilization) and interim source removal as part of the ISRA activities occurred in this area between 2009 and 2012. The Woolsey fire also affected this watershed in 2018. Limited runoff has been discharged at Outfall 008 since the 2012 completion of ISRA activities that included interim identification, evaluation, remediation or stabilization, and restoration of areas containing soil contaminated with COCs. Installation of new erosion and sediment controls, revegetation, and unpaved road stabilization also took place in 2012.
Table 7 shows that the constituents measured at Outfall 008 that had the greatest number of concentration observations larger than the 2015 NELs were lead, copper, and mercury. The Figure 7 time series of concentration observations greater than the 2015 NELs show obvious decreases with time. The trend of the concentration counts greater than the 2015 NELs was significant during years without and including fires
(p = 0.015 and 0.004). The confidence limits of the probability plots of the early and later time periods show minor overlaps associated with years having zero values, resulting in a significant comparison result in years without fires (p = 0.042), but only marginally significant for years with fires (p = 0.06).
Stormwater runoff that discharges at Outfall 009 naturally flows to Arroyo Simi and then to Calleguas Creek. The Outfall 009 watershed had a variety of administrative and rocket engine test activities. The area was affected by the 2005 Topanga fire, but only a small portion of the Outfall 009 watershed area was directly affected by the 2018 Woolsey fire. The Northern Drainage, which flows through the Outfall 009 watershed, undergoes annual inspections to identify and correct any unstable areas. Debris removal, especially near the LOX and shooting range areas, occurred in 2007. Distributed stormwater controls were installed in this watershed starting in 2010/11 and proceeded for several years as critical subareas were identified. Runoff from portions of the paved helipad area were diverted to the Silvernale advanced stormwater treatment system beginning in 2012. Interim source removal actions (ISRA) to remove contaminated material was conducted in 2013, and NASA conducted demolition and contaminated material removal at test sites in 2015 through 2019. Barriers were also installed around critical treated wood utility poles in 2019, and utility poles no longer needed were removed in 2022.
Table 7 summarizes the concentration observations that were above the 2015 NELs at Outfall 009 for the period before the 2010/11 rain year, and for the period during and after the 2010/11 rain year, corresponding to the period before and after interim removal of contaminated materials and stormwater management in the Outfall 009 watershed. Figure 7 shows the time series of the high concentrations and a grouped probability plot contrasting the numbers of the high concentrations for these two periods. The trend of the high observations is shown to significantly decrease during years without the fires and with the fires (regression slope p = 0.0036 and 0.001) with time, and the probability plots also show that the early period had significantly larger numbers of high concentrations per year compared to the later period during years without the fires and including the fires (p = 0.023 and 0.009 using the Mann Whitney Rank Sum test).
Table 7 Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL Outfalls 008 and 009.
| pH (field) | Oil & grease | Nitrate + Nitrite as Nitrogen (N) | Nitrate as Nitrogen (N) | Gross alpha | Cadmium | Copper | Cyanide | Lead | |
| Threshold maximum 2015 (NEL) | 8.5 | 15 mg/L | 8 mg/L | 8 mg/L | 15 pCi/L | 4 µg/L | 14 µg/L | 9.5 µg/L | 5.2 µg/L |
| Threshold type 2015 (NEL) | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit |
| Max observed ratio OF008 | <1 | <1 | 1.08 | 1.08 | 1.72 | <1 | 1.29 | 1.58 | 23.08 |
| Count >2015 NEL | 0 | 0 | 2 | 2 | 3 | 0 | 5 | 1 | 16 |
| Count before 2010–2011 rain year | 0 | 0 | 0 | 0 | 2 | 0 | 2 | 0 | 11 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 3 |
| Count during and after 2010–2011 rain year | 0 | 0 | 2 | 2 | 1 | 0 | 3 | 1 | 5 |
| Count during Woolsey fire year | 0 | 0 | 2 | 2 | 1 | 0 | 2 | 1 | 3 |
| Max observed ratio OF009 | 1.04 | 1.07 | <1 | <1 | <1 | 2.30 | 3.00 | <1 | 50.00 |
| Count >2015 NEL | 1 | 1 | 0 | 0 | 0 | 1 | 3 | 0 | 20 |
| Count before 2010–2011 rain year | 1 | 1 | 0 | 0 | 1 | 1 | 2 | 0 | 13 |
| Count during Topanga fire year | 1 | 0 | 0 | 0 | 1 | 1 | 2 | 0 | 3 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 7 |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
Table 7 (cont.) Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL Outfalls 008 and 009 .
| Mercury | Nickel | Selenium | Thallium | Zinc | TCDD TEQ No DNQ | Chronic Toxicity, Selenastrum | Total | ||
| Threshold maximum 2015 (NEL) | 0.13 µg/L | 86 µg/L | 5 µg/L | 2 µg/L | 120 µg/L | 2.8×10-8 µg/L | 50% | ||
| Threshold type 2015 (NEL) | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | NPDES permit limit | ||
| Max observed ratio OF008 | 1.31 | <1 | 1.60 | <1 | 1.00 | 3.13 | <1 | ||
| Count >2015 NEL | 4 | 0 | 2 | 0 | 1 | 1 | 0 | 37 | |
| Count before 2010–2011 rain year | 4 | 0 | 2 | 0 | 0 | 1 | 0 | 22 | |
| Count during Topanga fire year | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 6 | |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 15 | |
| Count during Woolsey fire year | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 12 | |
| Max observed ratio OF009 | 1.62 | 1.98 | <1 | 3.50 | <1 | 20346.55 | 1.15 | ||
| Count >2015 NEL | 5 | 1 | 0 | 2 | 0 | 24 | 1 | 60 | |
| Count before 2010–2011 rain year | 5 | 0 | 0 | 2 | 0 | 14 | 0 | 40 | |
| Count during Topanga fire year | 1 | 0 | 0 | 1 | 0 | 3 | 0 | 13 | |
| Count during and after 2010–2011 rain year | 0 | 1 | 0 | 0 | 0 | 10 | 1 | 20 | |
| Count during Woolsey fire year* | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a | |

Figure 7 Time series of concentration observations greater than the 2015 NELs at Outfalls 008 and 009.
The most common constituents having high concentrations at Outfall 009 were dioxin, TCDD TEQ no DNQ (14 during the early period and 10 during the later period) and lead (13 during early period and 7 during later period). Other constituents included mercury (all 5 during the early period), copper (3, with 2 during the early period) and seven other constituents having one or two high observations during the 25-year period.
2.6 Outfall 011/001
Outfall 011 drains an area that had various historical industrial activities. It is located above the southern buffer zone that has Outfall 001, located near the SSFL property boundary, but also includes the discharges from Outfall 011. Therefore, the NELs at Outfall 011 were permit limits, while the NELs at Outfall 001 were benchmarks. Interim soil removal and perchlorate treatment occurred in the Outfall 011 watershed area in 2003. The Topanga fire affected both Outfall 011 and 001 watershed areas in 2005, and the Woolsey fire also affected both watershed areas in 2018. NASA demolition of rocket engine test structures and removal of contaminated materials from the Outfall 001 watershed area were carried out in 2015 and in 2021. Treated wood pole treatment barriers were installed at critical locations in 2020, and unused treated wood poles were removed in 2022. The advanced stormwater treatment system was installed at Outfall 011 in 2011 but was not extensively used beyond the storage ponds until 2021 due to low flows at that location.
Table 8 shows the number of concentration observations greater than the 2015 NELs at Outfalls 011 and 001 for the different periods corresponding to before and after interim contaminated material removal and stormwater management activities, while Figure 8 shows the time series, probability, and box and whisker plots of these high stormwater concentrations. The downgradient Outfall 001 data do not indicate a significant downward trend with time for years without fires and including fires (regression slope terms p = 0.39 and 0.37). Significant differences for the counts of high concentration observations for the two time periods using the Mann Whitney Rank Sum were not found for years without or including fires (p = 0.11 and 0.10). Similar plots for Outfall 011 observations also did not indicate significant trends for years without or including fires (p = 0.14 and 0.29) for the slope terms, but the Mann Whitney Rank Sum test did indicate significant differences between the high concentration counts for the two monitoring periods for years without or including fires (p = 0.045 and 0.01).
Table 8 Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL Outfalls 011 and 001.
| Total Residual Chlorine | Gross Alpha | Arsenic | Copper | Iron | Lead | Manganese | Mercury | TCDD TEQ No DNQ | Total | |
| Threshold maximum 2015 (NEL) | 0.1 mg/L | 15 pCi/L | 10 µg/L | 14 µg/L | 0.3 mg/L | 5.2 µg/L | 50 µg/L | 0.1 µg/L | 2.8×10-8 µg/L | |
| Threshold type 2015 (NEL) | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | Benchmark for OF001 permit limit for OF011 | |
| Max observed ratio OF011 | 1.50 | <1 | 1.10 | <1 | 36.67 | 1.69 | 3.40 | 1.60 | 6.12 | |
| Count >2015 NEL | 1 | 0 | 1 | 0 | 21 | 5 | 11 | 3 | 8 | 50 |
| Count before 2010–2011 rain year | 1 | 0 | 0 | 0 | 14 | 4 | 6 | 3 | 3 | 31 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 1 | 2 | 1 | 0 | 1 | 5 |
| Count during and after 2010–2011 rain year | 0 | 0 | 1 | 0 | 7 | 1 | 5 | 0 | 5 | 19 |
| Count during Woolsey fire year | 0 | 0 | 1 | 0 | 3 | 1 | 2 | 0 | 3 | 10 |
| Max observed ratio OF001 | 1.70 | 1.15 | <1 | 3.93 | 306.67 | <1 | 8.00 | 2.60 | 6.80 | |
| Count >2015 NEL | 1 | 2 | 0 | 2 | 33 | 0 | 21 | 9 | 16 | 84 |
| Count before 2010–2011 rain year | 1 | 1 | 0 | 1 | 18 | 0 | 11 | 9 | 10 | 51 |
| Count during Topanga fire year | 0 | 0 | 0 | 1 | 6 | 0 | 1 | 1 | 1 | 10 |
| Count during and after 2010–2011 rain year | 0 | 1 | 0 | 1 | 15 | 0 | 10 | 0 | 6 | 33 |
| Count during Woolsey fire year | 0 | 0 | 0 | 0 | 4 | 0 | 2 | 0 | 0 | 6 |

Figure 8 Time series and probability plots of high stormwater concentrations at Outfalls 011 and 001.
The constituents with the largest numbers of high concentration observations at Outfall 011 were iron (14 in the early period and 7 in the later period), mercury (3 in the early period and none in the later period), manganese (6 in the early period and 5 in the later period), TCDD (3 in the early period and 5 in the later period), and lead (4 in the early period and 1 in the later period). Similar constituents were also noted to be greater than the 2015 NELs at Outfall 001 (iron, manganese, TCDD, and mercury). The numbers of high concentrations at Outfall 001 were greater than at Outfall 011, reflecting contributions of critical contaminants from the intermediate buffer area between these two outfall monitoring locations.
2.7 Outfall 018/002
Outfall 018 is located at the downgradient edge of an area that had industrial activity, while Outfall 002 is located further downstream below the southern buffer zone near the SSFL property boundary, like Outfalls 011 and 001. The Topanga Fire in 2005 and the Woolsey Fire in 2018 both affected these two watershed areas. The Woolsey Fire caused damage to the Silvernale advanced stormwater treatment system which was repaired and operational by the following rain year. The Silvernale treatment system was initially in operation in 2012 and received runoff from the Outfall 018 watershed, along with pumped stormwater from the small northern outfall watershed areas (Outfalls 003 through 007, and 010) and from some paved helipad areas in the Outfall 009 watershed area. Treated wood pole barriers were placed in 2020 in the Outfall 002 watershed area. Interim contaminated material removal, including building and asphalt removal, occurred in the Outfall 018 watershed from 2015 to 2022.
Table 9 summarizes the observed outfall concentrations that were greater than the 2015 NELs (Outfall 018 has permit limits, while Outfall 002 has benchmarks). Figure 9 shows time series, probability, and box and whisker plots of the observations of concentrations greater than the 2015 NELs. The Outfall 002 time series of high concentrations had significant downward trends with time during years without the fires (regression slope term p = 0.04) but was not statistically significant when the fire years were considered (p = 0.27). The Outfall 018 trends were significant without and with the fire years (p = 0.01 and 0.002). Both probability plot’s confidence intervals show substantial overlaps for the smaller high concentration counts and were distinctly separated during years with more frequent high concentration observations. The Mann Whitney Rank Sum tests indicated significant differences based on the number of samples comparing the early to late monitoring period for Outfall 018 for years without and with fire years (p = 0.008 and 0.002) but was only marginally significant for the Outfall 002 comparisons (p = 0.06 and 0.10).
The constituents having the largest number of high concentrations were mercury (total of 5 at OF018 and 13 at OF002), lead (2 and 10), iron (9 and 30), manganese (6 and 10), and TCDD (TEQ no DNQ) (9 and 9). High counts of pentachlorophenol (0 and 12) and bis (2-ethylhexyl) phthalate (0 and 16) were also observed, but only during the early years at Outfall 002.
Table 9 Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL Outfalls 018 and 002.
| Total Dissolved Solids | Total Residual Chlorine | Biochemical Oxygen Demand (BOD) | Oil & grease | Nitrate + Nitrite as Nitrogen (N) | Sulfate | Gross alpha | Gross beta | Combined Radium-226 & Radium-229 | |
| Threshold maximum 2015 (NEL) | 950 mg/L | 0.1 mg/L | 30 mg/L | 15 mg/L | 8 mg/L | 300 mg/L | 15 pCi/L | 50 pCi/L | 5 pCi/L |
| Threshold type 2015 (NEL) | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 |
| Max observed ratio OF018 | <1 | 1.40 | <1 | 1.13 | <1 | <1 | <1 | <1 | <1 |
| Count >2015 NEL | 0 | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 0 |
| Count before 2010–2011 rain year | 0 | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 0 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Count during Woolsey fire year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Max observed ratio OF002 | 1.05 | 1.40 | 1.10 | <1 | 1.25 | 2.57 | 46.73 | 8.52 | 3.40 |
| Count >2015 NEL | 1 | 1 | 1 | 0 | 1 | 9 | 4 | 1 | 1 |
| Count before 2010–2011 rain year | 1 | 1 | 1 | 0 | 1 | 8 | 1 | 1 | 1 |
| Count during Topanga fire year | 0 | 0 | 1 | 0 | 1 | 0 | 0 | 0 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 1 | 3 | 0 | 0 |
| Count during Woolsey fire year | 0 | 0 | 0 | 0 | 0 | 1 | 3 | 0 | 0 |
Table 9 (cont.) Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL Outfalls 018 and 002.
| Arsenic | Barium | Beryllium | Cadmium | Copper | Cyanide | Iron | Lead | Manganese | Mercury | |
| Threshold maximum 2015 (NEL) | 10 µg/L | 1 µg/L | 4 µg/L | 3.1 µg/L | 14 µg/L | 8.5 µg/L | 0.3 mg/L | 5.2 µg/L | 50 µg/L | 0.1 µg/L |
| Threshold type 2015 (NEL) | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit or OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 |
| Max observed ratio OF018 | <1 | <1 | <1 | <1 | <1 | <1 | 40.00 | 1.58 | 4.20 | 2.60 |
| Count >2015 NEL | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 2 | 6 | 5 |
| Count before 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 5 | 2 | 5 | 5 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 0 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 4 | 0 | 1 | 0 |
| Count during Woolsey fire year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Max observed ratio OF002 | 3.50 | 2.30 | 2.75 | 2.23 | 7.14 | 2.12 | 326.67 | 59.62 | 220.00 | 3.20 |
| Count >2015 NEL | 4 | 1 | 1 | 1 | 5 | 2 | 30 | 10 | 10 | 13 |
| Count before 2010–2011 rain year | 3 | 1 | 1 | 1 | 2 | 2 | 9 | 6 | 4 | 12 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 1 | 2 | 2 | 0 | 0 |
| Count during and after 2010–2011 rain year | 1 | 0 | 0 | 0 | 3 | 0 | 21 | 4 | 6 | 1 |
| Count during Woolsey fire year | 1 | 0 | 0 | 0 | 3 | 0 | 6 | 4 | 4 | 1 |
Table 9 (cont.) Concentration observations greater than the 2015 NELs before and after interim contaminated material removal and stormwater management at SSFL Outfalls 018 and 002.
| Selenium | Zinc | 1,2-Dichloroethane | Alpha-BHC | Bis (2-ethylhexyl) Phthalate | n-Nitroso-dimethylamine | Penta- chlorophenol | TCDD TEQ No DNQ | Chronic Toxicity, Selenastrum | Total | |
| Threshold maximum 2015 (NEL) | 8.2 µg/L | 119 µg/L | 0.5 µg/L | 0.03 µg/L | 4 µg/L | 16 µg/L | 16.5 µg/L | 2.8X10-8 µg/L | 50% | |
| Threshold type 2015 (NEL) | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | Benchmark for OF002 permit limit for OF018 | |
| Max observed ratio OF018 | <1 | 2.27 | 4.80 | <1 | <1 | <1 | <1 | 3.88 | <1 | |
| Count >2015 NEL | 0 | 1 | 1 | 0 | 0 | 0 | 0 | 9 | 0 | 35 |
| Count before 2010–2011 rain year | 0 | 1 | 1 | 0 | 0 | 0 | 0 | 9 | 0 | 30 |
| Count during Topanga fire year | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 3 | 0 | 6 |
| Count during and after 2010–2011 rain year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5 |
| Count during Woolsey fire year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Max observed ratio OF002 | 1.34 | 6.64 | <1 | 3.33 | 25.00 | 1.25 | 3.03 | 1276.38 | 1.11 | |
| Count >2015 NEL | 1 | 4 | 0 | 7 | 16 | 5 | 12 | 9 | 1 | 151 |
| Count before 2010–2011 rain year | 0 | 1 | 0 | 7 | 16 | 5 | 12 | 3 | 0 | 100 |
| Count during Topanga fire year | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 8 |
| Count during and after 2010–2011 rain year | 1 | 3 | 0 | 0 | 0 | 0 | 0 | 6 | 1 | 51 |
| Count during Woolsey fire year | 1 | 3 | 0 | 0 | 0 | 0 | 0 | 2 | 0 | 29 |

Figure 9 Time series and probability plots of high concentrations at Outfalls 002 and 018.
3 Summary, Conclusions, and Future Activities
The stormwater trend analyses conducted for this paper focused on the comparisons of numbers of concentration observations greater than the 2015 NELs (as a normalizing procedure due to changing NELs with earlier permits) with interim removal of contaminated soils and materials, and the use of stormwater management practices. Most of the site changes have occurred since the 2010/11 rain year. Therefore, the basic analyses compared the observed stormwater quality for the rain years from 1998/99 to 2009/10 as the early period before most of the site changes vs. from 2010/11 to 2022/23 as the later period after the site changes. Other factors that may have affected the observed trends reported in this paper were associated with other changes that have occurred over the 25-year monitoring period examined in this paper, including:
- Changing permit requirements over the years, with generally increasing numbers of analytes being monitored in later years. This may therefore have increased the number of exceedances during the later post-stormwater monitoring activity period.
- Changing outfall stormwater sampling from manual grab sampling to flow-integrated sampling for the 2010/2011 rain year. This was done to better represent the complete runoff events, including sampling at the beginning of the events that would be missed with manual sampling due to delays in mobilizing the sampling crews to multiple locations that are widely spaced, allowing sampling during off-hours, and sampling during hazardous conditions. This was done as part of the 2009 Discharge Permit requirements for composite sampling. It was not possible to directly compare monitoring results for grab vs. automatic sampling using site data due to changing site conditions also occurring at that time. However, Maestre and Pitt (2006) compared concentrations collected using automatic samplers and manual sampling at residential, commercial, and industrial areas as reported in the National Stormwater Quality Database. They found that TSS concentrations using the automatic samplers were significantly higher for the residential and commercial areas compared to the concentrations using manual sampling, while not enough samples were available to show significant differences for the industrial areas. Therefore, it is possible that the use of the automatic samplers during the later sampling period at SSFL may have resulted in elevated concentrations compared to the earlier sampling period, also possibly leading to additional exceedance observations in the later monitoring period.
Even with these potentially data confusing factors that may have elevated the numbers of exceedances during the later monitoring period, the number of concentration observations greater than the 2015 NELs were found to actually be significantly greater during the early period before most of the interim contaminated material removal and stormwater management activities at SSFL compared to the later period, as shown on Table 10. This paper also examined:
- Changes in site rainfall during these two periods may affect stormwater runoff quality, but there were no significant differences associated with the annual rain depths or the number of qualifying rain events for monitoring during these two periods when the rain data were examined.
- The two fires on SSFL both resulted in large numbers of concentration observations greater than the 2015 NELs during the rain year containing the fire. The rain year prior to the Topanga fire had a larger number of concentration observations greater than the 2015 NELs, compared to the rain year with the Topanga fire result (88 high observations). However, the rain year including the 2018 Woolsey fire resulted in the largest number of concentration observations greater than the 2015 NELs during the later period (56 high observations). In addition, the record 2022/23 rain year did not result in an unusually large number of high concentrations compared to the trend of concentration observations greater than the 2015 NELs vs. rainfall amount. Most of the statistical analyses did not include the years with the fires, but some basic statistics did consider the fire years.
Table 10 Number of all constituent concentration observations greater than the 2015 NEL for Outfalls during early and late monitoring periods, without fires
(except as noted).
| Outfall Location | Early monitoring period | Late monitoring period |
| Outfall 003 | 10 | 0* |
| Outfall 004 | 23 | 0* |
| Outfall 005 | 24 | 0* |
| Outfall 006 | 17 | 0* |
| Outfall 007 | 18 | 0* |
| Outfall 010 | 18 | 3* |
| Outfall 008 | 17 | 2 |
| Outfall 009 | 31 | 16* |
| Outfall 018 | 27 | 2 |
| Outfall 002 | 85 | 14 |
| Outfall 011 | 29 | 11 |
| Outfall 001 | 50 | 22 |
| All outfalls combined without fire years | 349 | 70 |
| All outfalls combined with fire years | 437 | 126 |
The major factors found to affect the number of concentration observations greater than the 2015 NELs included:
- Diversion of northern outfall stormwater to the Silvernale advanced stormwater treatment facility resulted in almost complete elimination of stormwater discharges from those outfalls.
- The advanced stormwater treatment systems at Outfalls 011 and 018 resulted in decreased numbers of high concentration discharges from these outfalls, even with the increased diverted flows from the northern outfalls (and a portion of the helipad above Outfall 009) to the Outfall 018 Silvernale advanced stormwater treatment system.
- The Topanga fire in 2005 and the Woolsey fire in 2018 resulted in large increases in the numbers of high concentrations greater than the 2015 NELs during the rain year with the fires compared to other rain years in the monitoring periods. The early monitoring period had one year with a greater number of high concentrations than the year of the Topanga fire, but the Woolsey fire rain year had the largest number of high concentrations for any of the rain years during the later monitoring period. The stormwater characteristics during the rain years following the fires were similar to typical conditions.
- The distributed stormwater controls and interim contaminated soil removal activities resulted in large decreases in the numbers of high stormwater concentrations at Outfalls 008 and 009.
The constituents comprising about 90% of the high concentrations greater than the 2015 NELs during the early monitoring period without the Topanga fire were relatively diverse, including (in order of abundance compared to the total number of high concentrations for all constituents combined): mercury (28%), iron (16%), TCDD (TEQ no DNQ) (14%), lead (9.5%), manganese (8.6%), pentachlorophenol (3.4%), sulfate (2.6%), bis (2-ethylhexyl) phthalate (2.6%), copper (2.3%), gross beta (1.7%), and antimony (1.7%). After the interim contaminated material removal and use of stormwater controls, the numbers of high concentrations greater than the 2015 NELs were greatly reduced, and the number of constituents comprising about 90% of these high concentrations were also greatly reduced (for years without the Woolsey fire): iron (40%), TCDD (TEQ no DNQ) (26%), lead (14%), and manganese (10%). Iron was removed from the 2023 discharge permit as it was determined to be associated with non-industrial background natural soils in the region.
3.1 Changes in stormwater exceedances of constituents of concern
The following are summaries associated with constituents of most interest in SSFL stormwater:
Gross alpha and gross beta high concentration occurrences are summarized on Table 11, and strontium-90 high concentration occurrences are summarized on Table 12. These constituents represent only a few of the total observations greater than the 2015 NELs but are of great interest to the stakeholders. These radioactive constituents had a total of 13 values greater than the 2015 NELs during the early monitoring period and decreased to three values (all gross alpha) greater than the 2015 NELs during the late monitoring period.
Table 11 Numbers of gross alpha and gross beta values >2015 NELs, without fires (except as noted).
| Outfall Location | Early monitoring period gross alpha (1.1% of total) | Late monitoring period gross alpha (1.4 % of total) | Early monitoring period for gross beta (1.7% of total) | Late monitoring period for gross beta (<0.1% of total) |
| Outfall 003 | 0 | 0 | 1 | 0 |
| Outfall 004 | 0 | 0 | 1 | 0 |
| Outfall 005 | 0 | 0 | 0 | 0 |
| Outfall 006 | 0 | 0 | 1 | 0 |
| Outfall 007 | 0 | 0 | 2 | 0 |
| Outfall 010 | 0 | 0 | 0 | 0 |
| Outfall 008 | 2 | 0 | 0 | 0 |
| Outfall 009 | 0 | 0 | 0 | 0 |
| Outfall 018 | 0 | 0 | 0 | 0 |
| Outfall 002 | 1 | 0 | 1 | 0 |
| Outfall 011 | 0 | 0 | 0 | 0 |
| Outfall 001 | 1 | 1 | 0 | 0 |
| All outfalls combined | 4 | 1 | 6 | 0 |
| All outfalls combined with fire years | 5 | 3 | 6 | 0 |
Table 12 Numbers of strontium-90 values >2015 NELs, without fires (except as noted).
| Outfall Location | Early monitoring period (0.3% of total) |
Late monitoring period (<0.1% of total) |
| Outfall 003 | 1 | 0 |
| Outfall 004 | 0 | 0 |
| Outfall 005 | 0 | 0 |
| Outfall 006 | 0 | 0 |
| Outfall 007 | 0 | 0 |
| Outfall 010 | 0 | 0 |
| Outfall 008 | 0 | 0 |
| Outfall 009 | 0 | 0 |
| Outfall 018 | 0 | 0 |
| Outfall 002 | 0 | 0 |
| Outfall 011 | 0 | 0 |
| Outfall 001 | 0 | 0 |
| All outfalls combined | 1 | 0 |
| All outfalls combined with fire years | 2 | 0 |
Few of these values exceeded the specific permit limits as the regulated permit limits are calculated based on long term averages and not single events, and they also require supporting specific compound analyses to identify anthropogenic vs. natural sources. During the late monitoring period, no gross beta or strontium-90 concentrations greater than the 2015 NELs were detected, even during the Woolsey fire year. One high gross alpha value was detected during the late non-fire monitoring period, and two high values were detected during the year of the Woolsey fire. The observations of high concentrations for these constituents were greater during the early monitoring period and were reduced after the interim contaminated material removal and stormwater management, as reflected in the late monitoring period data.
Table 13 summarizes the dioxin (TCDD TEQ no DNQ) observations greater than the 2015 NELs by outfall and monitoring period. Most of the high values were associated with the northern outfalls combined (Outfalls 003 through 007 plus 010) and Outfall 009 during the early period (31 out of 50). After the interim contaminated material removal and after stormwater from the northern outfalls were diverted to the Silvernale advanced treatment system at Outfall 018, the high dioxin discharge observations from these northern areas were eliminated at those locations, except for two at Outfall 010. The Outfall 018 discharges (after the Silvernale advanced stormwater treatment) had no high dioxin discharges, even with the additional diverted flows from the northern outfalls and a portion of the paved helipad in the Outfall 009 watershed. The 15 Outfall 009 high dioxin observations during the early monitoring period were reduced to 8 high dioxin observations during the late monitoring period after the distributed stormwater controls were installed and after the helipad flow diversions to the Silvernale treatment plant. The year with the Topanga fire had 18 high dioxin concentration observations and the year with the Woolsey fire had 5 high dioxin concentration observations. Dioxin high concentrations also made up about 14% of the total non-fire early monitoring period high concentration observations (3rd most abundant) and about 26% of the total non-fire late monitoring period concentration observations (2nd most abundant).
Table 13 Numbers of TCDD TEQ No DNQ concentration observations >2015 NEL, without fires (except as noted).
| Outfall location | Early monitoring period (14% of total) |
Late monitoring period (26% of total) |
| Outfall 003 | 1 | 0 |
| Outfall 004 | 3 | 0 |
| Outfall 005 | 2 | 0 |
| Outfall 006 | 2 | 0 |
| Outfall 007 | 1 | 0 |
| Outfall 010 | 7 | 2 |
| Outfall 008 | 1 | 0 |
| Outfall 009 | 15 | 8 |
| Outfall 018 | 6 | 0 |
| Outfall 002 | 6 | 1 |
| Outfall 011 | 2 | 3 |
| Outfall 001 | 4 | 4 |
| All outfalls combined | 50 | 18 |
| All outfalls combined with fire years | 68 | 23 |
Table 14 shows the numbers of high concentration observations greater than the 2015 NELs for lead for non-fire conditions. Lead was the fourth most abundant constituent having high concentration observations during the early monitoring period (about 10% of the total) and was the third most abundant constituent having high concentrations greater than the 2015 NELs during the later monitoring period (about 14% of the total). Most of the high lead concentrations occurred at Outfalls 008 and 009 (9 and 10 respectively out of 33) which were significantly reduced during the later monitoring period after the interim contaminated material removal and the use of the distributed controls in those areas (1 and 5 respectively out of 10). Large numbers of high lead concentrations were also observed during the two years with fires, 18 during the early Topanga fire year and nine during the later Woolsey fire year. The Imminent and Substantial Endangerment (ISE) Clean-up at the historical shooting range in the Outfall 009 watershed recently completed further reduced the number of lead concentration observations greater than the 2015 NEL at Outfall 009 to zero during the last monitoring period (2025/26, not shown in this paper but will be presented in the annual report submitted to the regulatory agencies.)
Table 14 Numbers of lead concentration observations >2015 NEL, without fires (except as noted).
| Outfall location | Early monitoring period (9.5% of total) |
Late monitoring period (14% of total) |
| Outfall 003 | 0 | 0 |
| Outfall 004 | 0 | 0 |
| Outfall 005 | 0 | 0 |
| Outfall 006 | 0 | 0 |
| Outfall 007 | 1 | 0 |
| Outfall 010 | 3 | 1 |
| Outfall 008 | 9 | 1 |
| Outfall 009 | 10 | 5 |
| Outfall 018 | 2 | 0 |
| Outfall 002 | 2 | 0 |
| Outfall 011 | 2 | 0 |
| Outfall 001 | 4 | 3 |
| All outfalls combined | 33 | 10 |
| All outfalls combined with fire years | 51 | 19 |
Table 15 summarizes the high copper concentration observations greater than the 2015 NELs for the years without fires during the early and late monitoring periods. Copper accounted for about 2% of the total early monitoring period high concentration observations and about 3% of the total late monitoring period high concentration observations. Individual outfalls had 0, 1 or 2 high copper concentration observations during either the early or late monitoring periods. Five high copper observations (out of the 8 total) occurred at the northern outfalls combined (Outfalls 003 through 007 plus 010) during the early monitoring period and were reduced to zero during the late monitoring period after their diversions to the Silvernale stormwater treatment plant at Outfall 018. Outfall 018 had zero high copper concentration observations during both the early and late monitoring periods, even after the increased flows diverted from the northern outfalls during the late monitoring period. The numbers of high copper concentration observations increased substantially during the fire years, with 10 during the year of the Topanga fire and 5 during the year of the Woolsey fire.
Table 15 Numbers of copper concentration observations >2015 NEL, without fires (except as noted).
| Outfall Location | Early monitoring period (2.3% of total) |
Late monitoring period (2.9% of total) |
| Outfall 003 | 0 | 0 |
| Outfall 004 | 1 | 0 |
| Outfall 005 | 1 | 0 |
| Outfall 006 | 0 | 0 |
| Outfall 007 | 2 | 0 |
| Outfall 010 | 1 | 0 |
| Outfall 008 | 1 | 1 |
| Outfall 009 | 0 | 1 |
| Outfall 018 | 0 | 0 |
| Outfall 002 | 2 | 0 |
| Outfall 011 | 0 | 0 |
| Outfall 001 | 0 | 0 |
| All outfalls combined | 8 | 2 |
| All outfalls combined with fire years | 18 | 7 |
Table 16 shows that the early period Northern Outfalls had the greatest numbers of concentration observations greater than the 2015 NEL for mercury (62 of the 97 high mercury observations). Mercury accounted for most of the high concentration observations greater than the 2015 NELs during the early monitoring period (about 28%). Outfall 002 also had a large number of high mercury observations during the early monitoring period (12). There were no high mercury concentration observations during the late monitoring period, after the interim contaminated material removal and use of stormwater controls. Eight high mercury concentrations were observed during the year of the Topanga fire while 1 high mercury concentration was observed during the year of the Woolsey fire. It should be noted that many of the early mercury concentrations were obtained using analytical methods that had poor detection limits and were unreliable.
Table 16 Numbers of mercury concentration observations >2015 NEL, without fires (except as noted).
| Outfall Location | Early monitoring period (28% of total) |
Late monitoring period (<0.1% of total) |
| Outfall 003 | 7 | 0 |
| Outfall 004 | 18 | 0 |
| Outfall 005 | 16 | 0 |
| Outfall 006 | 8 | 0 |
| Outfall 007 | 8 | 0 |
| Outfall 010 | 5 | 0 |
| Outfall 008 | 3 | 0 |
| Outfall 009 | 4 | 0 |
| Outfall 018 | 5 | 0 |
| Outfall 002 | 12 | 0 |
| Outfall 011 | 3 | 0 |
| Outfall 001 | 8 | 0 |
| All outfalls combined | 97 | 0 |
| All outfalls combined with fire years | 105 | 1 |
Table 17 shows the data for iron and manganese. These constituents were only monitored at Outfalls 001, 002, 011, and 018 per the NPDES discharge permit monitoring requirements. Iron had the second highest number of high concentration observations during the early monitoring period (about 16% of the total) and had the greatest number of high concentration observations during the late monitoring period (about 40%), even considering their reduced number of monitoring locations. A total of 55 high iron concentrations were observed during the early monitoring period, which was reduced to 28 during the late monitoring period. Ten high iron concentrations were observed during the year of the Topanga fire, and 13 high iron concentrations were observed during the year of the Woolsey fire.
Manganese accounted for about 9% of the total high concentration observations during the early monitoring period (ranked 5th) and accounted for about 10% of the total high concentration observations during the later monitoring period (ranked fourth). During the non-fire early monitoring years, 33 high manganese concentrations were observed, which were reduced to 7 during the late monitoring period. Three high manganese concentrations were observed during the year of the Topanga fire and 8 were observed during the year of the Woolsey fire. Based on the source investigations and supporting evaluations, these two constituents, which account for about half of the total current concentration observations greater than the 2015 NELs, are likely from background soil sources and not from any historical SSFL site activities.
Table 17 Numbers of iron and manganese concentration observations >2015 NELs, without fires (except as noted).
| Outfall location* | Early monitoring period iron (16% of total) |
Late monitoring period iron (40% of total) |
Early monitoring period for manganese (8.6% of total) |
Late monitoring period for manganese (10% of total) |
| Outfall 018 | 7 | 1 | 4 | 0 |
| Outfall 002 | 15 | 12 | 6 | 0 |
| Outfall 011 | 16 | 5 | 5 | 3 |
| Outfall 001 | 17 | 10 | 15 | 4 |
| All outfalls combined | 55 | 28 | 30 | 7 |
| All outfalls combined with fire years | 65 | 41 | 33 | 15 |
Paired t-tests were used to calculate the significance of the differences between the early and late monitoring period numbers of high concentration observations greater than the 2015 NELs during the non-fire years for all the outfalls, reflecting the benefits of the interim contaminated soil removal and use of the stormwater controls. Constituents with sufficient data and having significant (p ≤ 0.05) decreases when early vs. late monitoring period data were compared included: gross beta, copper, lead, iron, manganese, mercury, TCDD TEQ no DNQ. Similar tests were also conducted to compare the annual average number of high constituent observations during the early and late monitoring period vs. the years of the Topanga and Woolsey fires. Fewer data were available for these analyses considering the decreased areas affected by the Woolsey fire. The following constituents have sufficient data and have significant (p ≤ 0.05) increases in the numbers of high concentrations during the fire years compared to average non-fire years: iron (late), copper (early), lead (early and late), TCDD TEQ no DNQ (early), and for all constituents combined (early and late).
In August 2022, a Memorandum of Understanding (MOU) was adopted as part of a comprehensive framework that establishes specific clean-up protocols and timelines for Boeing and involves an agreement between Boeing and the Department of Toxic Substances Control (DTSC). The MOU outlines additional responsibilities for the Surface Water Expert Panel including modeling stormwater quality at SSFL outfalls that Boeing clean-up areas drain to, establishing background stormwater concentration thresholds, and designing a post-clean-up stormwater monitoring plan within Boeing areas of SSFL. The panel’s focus regarding control measures as the site moves into full scale remediation will focus more on erosion and sediment controls and keeping soil onsite.
Acknowledgements
The authors would like to thank Jeff Wokurka, Mark Spenard, Debbie Taege, Paul Costa, Lori Blair, Randy Dean, the Jacob & Hefner team, and other SSFL site staff and consultants who over the years have supported the interim contaminated material removal, and the design, implementation, maintenance, and monitoring of the stormwater treatment controls discussed in this paper, and as recommended by the Storm Water Expert Panel. Those supporting the SWEP’s efforts and the paper’s authors with technical stormwater control design, data processing, and analysis include Dan Bourdeau, Curtis Fang, Jai Panthail, Paul Hobson, Olivia Lincoln, and Stacy Luell. We also thank the Los Angeles Regional Water Quality Control Board and staff for their continued support of the SWEP and trust in us to serve as an independent technical panel with the receiving waters and residents’ best interests at heart. We also thank the members of the public who have attended our meetings and site visits, and who have offered comments, many of whom have been regular attendees since the panel started. We also thank the manuscript reviewers whose comments are greatly appreciated.
References
- Boeing Company. 2021a. “Third Quarter 2021 NPDES Discharge Monitoring Report.” Compliance File CI-6027 and NPDES No. CA0001309. Santa Susana Field Laboratory, Ventura County, California. November 15.
- Boeing Company. 2021b. “Fourth Quarter 2021 NPDES Discharge Monitoring Report.” Compliance File CI-6027 and NPDES No. CA0001309. Santa Susana Field Laboratory, Ventura County, California. February 15.
- Boeing Company. 2022a. “First Quarter 2022 NPDES Discharge Monitoring Report, Compliance File CI-6027 and NPDES No. CA0001309. Santa Susana Field Laboratory, Ventura County, California. May 15.
- Boeing Company. 2022b. “Second Quarter 2022 NPDES Discharge Monitoring Report.” Compliance File CI-6027 and NPDES No. CA0001309. Santa Susana Field Laboratory, Ventura County, California. August 15.
- Haley & Aldrich, Inc. 2021. “2021/22 Rainy Season Sampling and Analysis Plan (SAP) Updates, Best Management Practice (BMP) Monitoring Program.” Prepared for the Boeing Company, Ventura County, California.
- LARWQCB. 2015. “Transmittal of the Waste Discharge Requirements (WRDs) and National Pollutant Discharge Elimination System (NPDES) Permit for the Boeing Company.” Santa Susana Field Laboratory, Canoga Park, CA, NPDES No. CA0001309, CI NO 6027. February 23.
- Maestre, A. and R.E. Pitt. 2006. “Identification of Significant Factors Affecting Stormwater Quality using the National Stormwater Quality Database.” Journal of Water Management Modeling R225:13. http://dx.doi.org/10.14796/JWMM.R225-13
- MWH et al. 2015. “ISRA Performance Monitoring and BMP Monitoring for the Outfalls 008 and 009 Watersheds, 2014/2015 Rainy Season.” Prepared for the Boeing Company, Ventura County, California.
- Pitt, R.E., M. Straight, S. Isaac, B. Steets, M. Otto, R. Gearheart, J. Jones, M. Josselyn, and M.K. Stenstrom. 2026. “Site Management and Stormwater Controls Over Twenty-Five Years at an Industrial Site, Part 1.” Journal of Water Management Modeling 34: C600. https://doi.org/10.14796/JWMM.C600
- Pitt, R., M. Otto, A. Questad, S. Isaac, M. Colyar, B. Steets, R. Gearheart, et al. 2021. “Laboratory Media Test Comparisons to Long-Term Performance of Biofilter and Media Filter Treatment-Train Stormwater Controls.” Journal of Sustainable Water in the Built Environment 7 (4): 04021015.
- Pitt, R., M. Otto, A. Questad, S. Isaac, M. Colyar, B. Steets, R. Gearheart, et al. 2022. “Performance Changes during Long-Term Monitoring of Full-Scale Media Filter Stormwater Controls at an Industrial Site.” Journal of Sustainable Water in the Built Environment 8 (1): 04021019.
- Santa Susana Surface Water Expert Panel and Geosyntec Consultants. 2015. “Site-Wide Stormwater Work Plan and 2014/15 Annual Report.” The Boeing Company, Santa Susana Field Laboratory, Ventura County, CA. September.
- Santa Susana Surface Water Expert Panel and Geosyntec Consultants. 2019. “Site-Wide Stormwater Work Plan and 2018/19 Annual Report.” The Boeing Company, Santa Susana Field Laboratory, Ventura County, CA. September.